Read more1C X 35 Sq.mm NEW
Nexans ref. 21035QXZVABZ1BE0
- Conductor cross-section: 35 mm²
- Approximate weight: 559 kg/km
- Nominal outer diameter: 17.0 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 176 A
- Permissible current rating when buried: 129 A
1C X 50 Sq.mm NEW
Nexans ref. 21050QXZVABZ1BE0
- Conductor cross-section: 50 mm²
- Approximate weight: 707 kg/km
- Nominal outer diameter: 18.4 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 216 A
- Permissible current rating when buried: 153 A
1C X 70 Sq.mm NEW
Nexans ref. 21070QXZVABZ1BE0
- Conductor cross-section: 70 mm²
- Approximate weight: 943 kg/km
- Nominal outer diameter: 20.4 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 279 A
- Permissible current rating when buried: 188 A
1C X 95 Sq.mm NEW
Nexans ref. 21095QXZVABZ1BE0
- Conductor cross-section: 95 mm²
- Approximate weight: 1220 kg/km
- Nominal outer diameter: 22.1 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 342 A
- Permissible current rating when buried: 226 A
1C X 120 Sq.mm NEW
Nexans ref. 21120QXZVABZ1BE0
- Conductor cross-section: 120 mm²
- Approximate weight: 1477 kg/km
- Nominal outer diameter: 23.9 mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 400 A
- Permissible current rating when buried: 257 A
1C X 150 Sq.mm NEW
Nexans ref. 21150QXZVABZ1BE0
- Conductor cross-section: 150 mm²
- Approximate weight: 1772 kg/km
- Nominal outer diameter: 25.6 mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 464 A
- Permissible current rating when buried: 287 A
1C X 185 Sq.mm NEW
Nexans ref. 21185QXZVABZ1BE0
- Conductor cross-section: 185 mm²
- Approximate weight: 2177 kg/km
- Nominal outer diameter: 28.2 mm
- Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
- Permissible current rating in open air: 533 A
- Permissible current rating when buried: 324 A
1C X 240 Sq.mm NEW
Nexans ref. 21240QXZVABZ1BE0
- Conductor cross-section: 240 mm²
- Approximate weight: 2737 kg/km
- Nominal outer diameter: 30.5 mm
- Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
- Permissible current rating in open air: 634 A
- Permissible current rating when buried: 375 A
1C X 300 Sq.mm NEW
Nexans ref. 21300QXZVABZ1BE0
- Conductor cross-section: 300 mm²
- Approximate weight: 3348 kg/km
- Nominal outer diameter: 33.0 mm
- Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
- Permissible current rating in open air: 736 A
- Permissible current rating when buried: 419 A
1C X400 Sq.mm NEW
Nexans ref. 21400QXZVABZ1BE0
- Conductor cross-section: 400 mm²
- Approximate weight: 4248 kg/km
- Nominal outer diameter: 37.2 mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 868 A
- Permissible current rating when buried: 717 A
1C X 500 Sq.mm NEW
Nexans ref. 21500QXZVABZ1BE0
- Conductor cross-section: 500 mm²
- Approximate weight: 5375 kg/km
- Nominal outer diameter: 40.9 mm
- Max. DC resistance of the conductor at 20°C: 0.036 Ohm/km
- Permissible current rating in open air: 998 A
- Permissible current rating when buried: 791 A
1C X630 Sq.mm NEW
Nexans ref. 21630QXZVABZ1BE0
- Conductor cross-section: 630 mm²
- Approximate weight: 6771 kg/km
- Nominal outer diameter: 45.2 mm
- Max. DC resistance of the conductor at 20°C: 0.028 Ohm/km
- Permissible current rating in open air: 1151 A
- Permissible current rating when buried: 861 A
Description
Description
Standards
-
ProductIEC 60502-1
-
TestIEC 60332-3-22 Cat.A
Scope
The Cables covered in this specification are used for electricity supply in low voltage installation system. They are well adapted to underground use in industrial applications where chemical and mechanical protections are needed (refinery areas, chemical plants...).
Design
1. Conductor
Plain annealed high-conductivity Stranded Copper Class 2 conforming to BS EN 60228
2. Insulation
XLPE
3. Filling or Bedding
Extruded PVC
4. Armour
Single layer of Aluminium Round Wires (AWA)
5. Outer Sheath
Flame Retardant PVC
- Flame retardant : IEC60332-3-22 CAT A
- Colour : Black
Marking (by Embossing/Engraving)
NO.OF CORES X Sq.mm CU/XLPE/AWA/PVC FR 600/1000 V IEC 60502-1 IEC 60332-3-22 MADE IN QATAR QICC-NEXANS Years Meters
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania