Read more2C X 1.5 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22002SXZHSH30BS0
- Conductor cross-section: 1.5 mm²
- Approximate weight: 209 kg/km
- Nominal outer diameter: 11.2 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 25 A
- Permissible current rating when buried: 23 A
- Voltage drop, 3 conductors: 22.8 V/A.km
2C X 2.5 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22003SXZHSH30BS0
- Conductor cross-section: 2.5 mm²
- Approximate weight: 270 kg/km
- Nominal outer diameter: 12.6 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 30 A
- Voltage drop, 3 conductors: 14.0 V/A.km
2C X 4 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22004SXZHSH30BS0
- Conductor cross-section: 4 mm²
- Approximate weight: 334 kg/km
- Nominal outer diameter: 13.7 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 44 A
- Permissible current rating when buried: 39 A
- Voltage drop, 3 conductors: 8.7 V/A.km
2C X 6 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22006SXZHSH30BS0
- Conductor cross-section: 6 mm²
- Approximate weight: 392 kg/km
- Nominal outer diameter: 14.8 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 56 A
- Permissible current rating when buried: 49 A
- Voltage drop, 3 conductors: 5.9 V/A.km
2C X 10 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22010SXZHSH30BS0
- Conductor cross-section: 10 mm²
- Approximate weight: 522 kg/km
- Nominal outer diameter: 16.4 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 78 A
- Permissible current rating when buried: 65 A
- Voltage drop, 3 conductors: 3.5 V/A.km
2C X 16 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22016SXZHSH30BS0
- Conductor cross-section: 16 mm²
- Approximate weight: 767 kg/km
- Nominal outer diameter: 18.9 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 99 A
- Permissible current rating when buried: 84 A
- Voltage drop, 3 conductors: 2.2 V/A.km
2C X 25 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22025SXZHSH30BS0
- Conductor cross-section: 25 mm²
- Approximate weight: 1056 kg/km
- Nominal outer diameter: 22.4 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 131 A
- Permissible current rating when buried: 107 A
- Voltage drop, 3 conductors: 1.7 V/A.km
2C X 35 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22035SXZHSH30BS0
- Conductor cross-section: 35 mm²
- Approximate weight: 1466 kg/km
- Nominal outer diameter: 25.5 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 162 A
- Permissible current rating when buried: 129 A
- Voltage drop, 3 conductors: 1.2 V/A.km
2C X 50 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22050SXZHSH30BS0
- Conductor cross-section: 50 mm²
- Approximate weight: 1823 kg/km
- Nominal outer diameter: 28.6 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 197 A
- Permissible current rating when buried: 153 A
- Voltage drop, 3 conductors: 0.89 V/A.km
2C X 70 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22070SXZHSH30BS0
- Conductor cross-section: 70 mm²
- Approximate weight: 2688 kg/km
- Nominal outer diameter: 33.5 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 251 A
- Permissible current rating when buried: 188 A
- Voltage drop, 3 conductors: 0.6 V/A.km
2C X 95 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22095SXZHSH30BS0
- Conductor cross-section: 95 mm²
- Approximate weight: 3282 kg/km
- Nominal outer diameter: 37.1 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 304 A
- Permissible current rating when buried: 226 A
- Voltage drop, 3 conductors: 0.45 V/A.km
2C X 120 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22120SXZHSH30BS0
- Conductor cross-section: 120 mm²
- Approximate weight: 3885 kg/km
- Nominal outer diameter: 40.5 mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 353 A
- Permissible current rating when buried: 257 A
- Voltage drop, 3 conductors: 0.37 V/A.km
2C X 150 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22150SXZHSH30BS0
- Conductor cross-section: 150 mm²
- Approximate weight: 4761 kg/km
- Nominal outer diameter: 44.0 mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 406 A
- Permissible current rating when buried: 287 A
- Voltage drop, 3 conductors: 0.3 V/A.km
2C X 185 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22185SXZHSH30BS0
- Conductor cross-section: 185 mm²
- Approximate weight: 5952 kg/km
- Nominal outer diameter: 49.7 mm
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Permissible current rating in open air: 463 A
- Permissible current rating when buried: 324 A
- Voltage drop, 3 conductors: 0.26 V/A.km
2C X 240 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22240SXZHSH30BS0
- Conductor cross-section: 240 mm²
- Approximate weight: 7466 kg/km
- Nominal outer diameter: 54.3 mm
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Permissible current rating in open air: 546 A
- Permissible current rating when buried: 375 A
- Voltage drop, 3 conductors: 0.21 V/A.km
2C X 300 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22300SXZHSH30BS0
- Conductor cross-section: 300 mm²
- Approximate weight: 8729 kg/km
- Nominal outer diameter: 59.5 mm
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
- Permissible current rating in open air: 628 A
- Permissible current rating when buried: 419 A
- Voltage drop, 3 conductors: 0.18 V/A.km
2C X 400 Sq.mm CU/XLPE/SWA/HFFR NEW
Nexans ref. 22400SXZHSH30BS0
- Conductor cross-section: 400 mm²
- Approximate weight: 10822 kg/km
- Nominal outer diameter: 67.6 mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 731 A
- Permissible current rating when buried: 439 A
- Voltage drop, 3 conductors: 0.17 V/A.km
Description
Description
Standards
-
ProductBS 6724
-
TestIEC 60332-3-24 Cat.C
Scope
This specification covers two core, XLPE insulated cables for use on the Qatar Power Systems ,Street lightning and Small wiring systems. These cables are complying with BS 6724 and QCS 2014 Standards .
Design
1. Conductor
Plain annealed high-conductivity Stranded Copper Class 2 conforming to BS EN 60228
2. Insulation
XLPE insulation Type GP8 conforming to BS 7655-1
3. Filling or Bedding
Extruded HFFR
4. Armour
Single layer of Galvanised Steel Wires (GSWA)
5. Outer Sheath
Halogen Free Flame Retardant (HFFR)
- Flame retardant : IEC60332-3-24 CAT C
- Colour : Black
Marking
NO.OF CORES X Sq.mm CU/XLPE/SWA/HFFR 600/1000 V BS 6724 MADE IN QATAR QICC-NEXANS Years Meters
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania