2-CORE XLPE,SWA,PVC SHEATHED CABLES AS PER QCS 2014

Products

2C X 1.5 NEW

Nexans ref. 22002FXZVSB09BS0

  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 236 kg/km
  • Nominal outer diameter: 11.2 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

2C X 2.5 NEW

Nexans ref. 22003FXZVSB09BS0

  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 304 kg/km
  • Nominal outer diameter: 12.6 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

2C X 4 NEW

Nexans ref. 22004FXZVSB09BS0

  • Conductor cross-section: 4 mm²
  • Approximate weight: 371 kg/km
  • Nominal outer diameter: 13.7 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 44 A
  • Permissible current rating when buried: 39 A
  • Voltage drop, 3 conductors: 8.7 V/A.km

 

2C X 6 NEW

Nexans ref. 22006FXZVSB09BS0

  • Conductor cross-section: 6 mm²
  • Approximate weight: 451 kg/km
  • Nominal outer diameter: 14.8 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 56 A
  • Permissible current rating when buried: 49 A
  • Voltage drop, 3 conductors: 5.9 V/A.km

 

2C X 10 NEW

Nexans ref. 22010FXZVSB09BS0

  • Conductor cross-section: 10 mm²
  • Approximate weight: 588 kg/km
  • Nominal outer diameter: 16.4 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 78 A
  • Permissible current rating when buried: 65 A
  • Voltage drop, 3 conductors: 3.5 V/A.km

 

2C X 16 NEW

Nexans ref. 22016FXZVSB09BS0

  • Conductor cross-section: 16 mm²
  • Approximate weight: 847 kg/km
  • Nominal outer diameter: 18.9 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 99 A
  • Permissible current rating when buried: 84 A
  • Voltage drop, 3 conductors: 2.2 V/A.km

 

2C X 25 NEW

Nexans ref. 22025FXZVSB09BS0

  • Conductor cross-section: 25 mm²
  • Approximate weight: 1194 kg/km
  • Nominal outer diameter: 22.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 131 A
  • Permissible current rating when buried: 107 A
  • Voltage drop, 3 conductors: 1.7 V/A.km

 

2C X 35 NEW

Nexans ref. 22035FXZVSB09BS0

  • Conductor cross-section: 35 mm²
  • Approximate weight: 1627 kg/km
  • Nominal outer diameter: 25.6 mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 162 A
  • Permissible current rating when buried: 129 A
  • Voltage drop, 3 conductors: 1.2 V/A.km

 

2C X 50 NEW

Nexans ref. 22050FXZ6SB09BS0

  • Conductor cross-section: 50 mm²
  • Approximate weight: 1829 kg/km
  • Nominal outer diameter: 28.3 mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 197 A
  • Permissible current rating when buried: 153 A
  • Voltage drop, 3 conductors: 0.89 V/A.km

 

2C X 70 NEW

Nexans ref. 22070FXZ6SB09BS0

  • Conductor cross-section: 70 mm²
  • Approximate weight: 2586 kg/km
  • Nominal outer diameter: 33.2 mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 251 A
  • Permissible current rating when buried: 188 A
  • Voltage drop, 3 conductors: 0.6 V/A.km

 

2C X 95 NEW

Nexans ref. 22095FXZ6SB09BS0

  • Conductor cross-section: 95 mm²
  • Approximate weight: 3282 kg/km
  • Nominal outer diameter: 36.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 304 A
  • Permissible current rating when buried: 226 A
  • Voltage drop, 3 conductors: 0.45 V/A.km

 

2C X 120 NEW

Nexans ref. 22120FXZ6SB09BS0

  • Conductor cross-section: 120 mm²
  • Approximate weight: 3965 kg/km
  • Nominal outer diameter: 40.2 mm
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 353 A
  • Permissible current rating when buried: 257 A
  • Voltage drop, 3 conductors: 0.37 V/A.km

 

2C X 150 NEW

Nexans ref. 22150FXZ6SB09BS0

  • Conductor cross-section: 150 mm²
  • Approximate weight: 4691 kg/km
  • Nominal outer diameter: 43.7 mm
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 406 A
  • Permissible current rating when buried: 287 A
  • Voltage drop, 3 conductors: 0.3 V/A.km

 

2C X 185 NEW

Nexans ref. 22185FXZ6SB09BS0

  • Conductor cross-section: 185 mm²
  • Approximate weight: 6110 kg/km
  • Nominal outer diameter: 49.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 463 A
  • Permissible current rating when buried: 324 A
  • Voltage drop, 3 conductors: 0.26 V/A.km

 

2C X 240 NEW

Nexans ref. 22240FXZ6SB09BS0

  • Conductor cross-section: 240 mm²
  • Approximate weight: 7379 kg/km
  • Nominal outer diameter: 54.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 546 A
  • Permissible current rating when buried: 375 A
  • Voltage drop, 3 conductors: 0.21 V/A.km

 

2C X 300 NEW

Nexans ref. 22300FXZ6SB09BS0

  • Conductor cross-section: 300 mm²
  • Approximate weight: 8885 kg/km
  • Nominal outer diameter: 59.2 mm
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • Permissible current rating in open air: 628 A
  • Permissible current rating when buried: 419 A
  • Voltage drop, 3 conductors: 0.18 V/A.km

 

Description

Description

Standards

  • International
    IEC 60332-1
  • National
    BS 5467

Scope

 This specification covers two core, XLPE insulated cables for use in Qatar Power Systems ,Street lighting and Small wiring systems. These cables are complying with BS 5467 and QCS 2014 Standards .

 

Design

 

1. Conductor

Plain annealed high-conductivity Stranded Copper Class 2 conforming to BS EN 60228

 

2. Insulation

XLPE insulation Type GP8 conforming to BS 7655-1

 

3. Filling or Bedding

 Extruded PVC

 

4. Armour

Single layer of Galvanised Steel Wires (GSWA)

 

5. Outer Sheath

Polyvinyl Chloride 'PVC'

 - Flame retardant : IEC60332-1

 - Colour :  Black

 

Marking

NO.OF CORES X Sq.mm CU/XLPE/SWA/PVC 600/1000 V  BS 5467 MADE IN QATAR QICC-NEXANS Years  Meters

 

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Stranded class 2
Conductor shape
Circular
Insulation
XLPE
Core identification
Red,Black
Inner sheath
PVC
Armour type
Galvanized steel wires
Outer sheath
PVC
Colour
Black
Halogen free
No

Dimensional characteristics

Dimensional characteristics

Number of cores
2

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV
Thermal soil resistivity dry zone
2.5 °K.m/W

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Bending factor when laying
12 (xD)
Ambient air temperature
30 °C
Ambient ground temperature
20 °C
Laying depth, center of system
700 mm
Max. pulling force during laying
50 N/mm2

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close