4-CORE XLPE,SWA,PVC SHEATHED CABLES AS PER IEC60502-1

Products

4C X 1.5 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24002BXZVSB09BD0

  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 358.3 kg/km
  • Nominal outer diameter: 13.8 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A

 

4C X 2.5 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24003BXZVSB09BD0

  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 437.1 kg/km
  • Nominal outer diameter: 15.1 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A

 

4C X 4 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24004BXZVSB09BD0

  • Conductor cross-section: 4 mm²
  • Approximate weight: 550.2 kg/km
  • Nominal outer diameter: 16.5 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 44 A
  • Permissible current rating when buried: 39 A

 

4C X 6 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24006BXZVSB09BD0

  • Conductor cross-section: 6 mm²
  • Approximate weight: 919 kg/km
  • Nominal outer diameter: 18.5 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 56 A
  • Permissible current rating when buried: 49 A

 

4C X 10 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24010BXZVSB09BD0

  • Conductor cross-section: 10 mm²
  • Approximate weight: 958.1 kg/km
  • Nominal outer diameter: 20.2 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 78 A
  • Permissible current rating when buried: 65 A

 

4C X 16 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24016BXZVSB09BD0

  • Conductor cross-section: 16 mm²
  • Approximate weight: 1363.2 kg/km
  • Nominal outer diameter: 23.1 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 99 A
  • Permissible current rating when buried: 84 A

 

4C X 25 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24025BXZVSB09BD0

  • Conductor cross-section: 25 mm²
  • Approximate weight: 1926.9 kg/km
  • Nominal outer diameter: 27.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 131 A
  • Permissible current rating when buried: 107 A

 

4C X 35 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24035BXZVSB09BD0

  • Conductor cross-section: 35 mm²
  • Approximate weight: 2432.7 kg/km
  • Nominal outer diameter: 29.6 mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 162 A
  • Permissible current rating when buried: 129 A

 

4C X 50 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24050BXZ6SB09BD0

  • Conductor cross-section: 50 mm²
  • Approximate weight: 2689.4 kg/km
  • Nominal outer diameter: 29.6 mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 197 A
  • Permissible current rating when buried: 153 A

 

4C X 70 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24070BXZ6SB09BD0

  • Conductor cross-section: 70 mm²
  • Approximate weight: 3852 kg/km
  • Nominal outer diameter: 34.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 251 A
  • Permissible current rating when buried: 188 A

 

4C X 95 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24095BXZ6SB09BD0

  • Conductor cross-section: 95 mm²
  • Approximate weight: 5010 kg/km
  • Nominal outer diameter: 38.6 mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 304 A
  • Permissible current rating when buried: 226 A

 

4C X 120 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24120BXZ6SB09BD0

  • Conductor cross-section: 120 mm²
  • Approximate weight: 6403.4 kg/km
  • Nominal outer diameter: 43.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 353 A
  • Permissible current rating when buried: 257 A

 

4C X 150 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24150BXZ6SB09BD0

  • Conductor cross-section: 150 mm²
  • Approximate weight: 7699.4 kg/km
  • Nominal outer diameter: 47.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 406 A
  • Permissible current rating when buried: 287 A

 

4C X 185 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24185BXZ6SB09BD0

  • Conductor cross-section: 185 mm²
  • Approximate weight: 9401.6 kg/km
  • Nominal outer diameter: 52.6 mm
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 463 A
  • Permissible current rating when buried: 324 A

 

4C X 240 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24240BXZ6SB09BD0

  • Conductor cross-section: 240 mm²
  • Approximate weight: 11857 kg/km
  • Nominal outer diameter: 58.7 mm
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 546 A
  • Permissible current rating when buried: 375 A

 

4C X 300 Sq.mm CU/XLPE/SWA/PVC NEW

Nexans ref. 24300BXZ6SB09BD0

  • Conductor cross-section: 300 mm²
  • Approximate weight: 14447 kg/km
  • Nominal outer diameter: 65.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • Permissible current rating in open air: 628 A
  • Permissible current rating when buried: 419 A

 

Description

Description

Standards

  • Product
    IEC 60502-1
  • Test
    IEC 60332-1

Scope

 This specification covers two core, XLPE insulated cables for use on the Low Voltage Power Systems ,Street lightning ans Small wiring systems. These cables are complying with IEC 60502-1

 

Design

 

1. Conductor

Plain annealed high-conductivity Stranded Copper Class 2 conforming to BS EN 60228

 

2. Insulation

XLPE

 

3. Filling or Bedding

 Extruded PVC

 

4. Armour

Single layer of Galvanised Steel Wires (GSWA)

 

5. Outer Sheath

Polyvinyl Chloride 'PVC'

 - Flame retardant : IEC60332-1

 - Colour :  Black

 

Marking

NO.OF CORES X Sq.mm CU/XLPE/SWA/PVC 600/1000 V  IEC 60502-1 MADE IN QATAR QICC-NEXANS Years  Meters

 

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Stranded class 2
Inner sheath
PVC
Armour type
Galvanized steel wires
Outer sheath
PVC
Colour
Black
Core identification
Red,Yellow,Blue,Black
Insulation
XLPE

Dimensional characteristics

Dimensional characteristics

Number of cores
4

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Bending factor when laying
12 (xD)
Ambient air temperature
30 °C
Ambient ground temperature
20 °C
Max. pulling force during laying
50 N/mm2

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close