4-CORE XLPE SWA HFFR SHEATHED CABLES AS PER QCS 2014
4-CORE XLPE SWA HFFR SHEATHED CABLES AS PER QCS 2014
4-CORE XLPE SWA HFFR SHEATHED CABLES AS PER QCS 2014
Read more4C X 1.5 Sq.mm
Nexans ref. 24002SXZHSH30BS0
- Conductor shape: Circular
- Conductor cross-section: 1.5 mm²
- Approximate weight: 279 kg/km
- Nominal outer diameter: 12.4 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 25 A
- Permissible current rating when buried: 23 A
- Voltage drop, 3 conductors: 22.8 V/A.km
4C X 2.5 Sq.mm
Nexans ref. 24003SXZHSH30BS0
- Conductor shape: Circular
- Conductor cross-section: 2.5 mm²
- Approximate weight: 369 kg/km
- Nominal outer diameter: 14.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 30 A
- Voltage drop, 3 conductors: 14.0 V/A.km
4C X 4 Sq.mm
Nexans ref. 24004SXZHSH30BS0
- Conductor shape: Circular
- Conductor cross-section: 4 mm²
- Approximate weight: 465 kg/km
- Nominal outer diameter: 15.4 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 44 A
- Permissible current rating when buried: 39 A
- Voltage drop, 3 conductors: 8.7 V/A.km
4C X 6 Sq.mm
Nexans ref. 24006SXZHSH30BS0
- Conductor shape: Circular
- Conductor cross-section: 6 mm²
- Approximate weight: 643 kg/km
- Nominal outer diameter: 17.6 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 56 A
- Permissible current rating when buried: 49 A
- Voltage drop, 3 conductors: 5.9 V/A.km
4C X 10 Sq.mm
Nexans ref. 24010SXZHSH30BS0
- Conductor shape: Circular
- Conductor cross-section: 10 mm²
- Approximate weight: 880 kg/km
- Nominal outer diameter: 19.3 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 78 A
- Permissible current rating when buried: 65 A
- Voltage drop, 3 conductors: 3.5 V/A.km
4C X 16 Sq.mm
Nexans ref. 24016SXZHSH30BS0
- Conductor shape: Circular
- Conductor cross-section: 16 mm²
- Approximate weight: 1170 kg/km
- Nominal outer diameter: 21.7 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 99 A
- Permissible current rating when buried: 84 A
- Voltage drop, 3 conductors: 2.2 V/A.km
4C X 25 Sq.mm
Nexans ref. 24025SXZHSH30BS0
- Conductor shape: Circular
- Conductor cross-section: 25 mm²
- Approximate weight: 1788 kg/km
- Nominal outer diameter: 26.8 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 131 A
- Permissible current rating when buried: 107 A
- Voltage drop, 3 conductors: 1.65 V/A.km
4C X 35 Sq.mm
Nexans ref. 24035SXZHSH30BS0
- Conductor shape: Circular
- Conductor cross-section: 35 mm²
- Approximate weight: 2242 kg/km
- Nominal outer diameter: 29.5 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 162 A
- Permissible current rating when buried: 129 A
- Voltage drop, 3 conductors: 1.15 V/A.km
4C X 50 Sq.mm
Nexans ref. 24050SXZHSH30BS0
- Conductor shape: Sector-shaped
- Conductor cross-section: 50 mm²
- Approximate weight: 2700 kg/km
- Nominal outer diameter: 29.7 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 197 A
- Permissible current rating when buried: 153 A
- Voltage drop, 3 conductors: 0.89 V/A.km
4C X 70 Sq.mm
Nexans ref. 24070SXZHSH30BS0
- Conductor shape: Sector-shaped
- Conductor cross-section: 70 mm²
- Approximate weight: 3862 kg/km
- Nominal outer diameter: 35.0 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 251 A
- Permissible current rating when buried: 188 A
- Voltage drop, 3 conductors: 0.6 V/A.km
4C X 95 Sq.mm
Nexans ref. 24095SXZHSH30BS0
- Conductor shape: Sector-shaped
- Conductor cross-section: 95 mm²
- Approximate weight: 5019 kg/km
- Nominal outer diameter: 38.7 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 304 A
- Permissible current rating when buried: 226 A
- Voltage drop, 3 conductors: 0.45 V/A.km
4C X 120 Sq.mm
Nexans ref. 24120SXZHSH30BS0
- Conductor shape: Sector-shaped
- Conductor cross-section: 120 mm²
- Approximate weight: 6370 kg/km
- Nominal outer diameter: 43.5 mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 353 A
- Permissible current rating when buried: 257 A
- Voltage drop, 3 conductors: 0.37 V/A.km
4C X 150 Sq.mm
Nexans ref. 24150SXZHSH30BS0
- Conductor shape: Sector-shaped
- Conductor cross-section: 150 mm²
- Approximate weight: 7663 kg/km
- Nominal outer diameter: 47.4 mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 406 A
- Permissible current rating when buried: 287 A
- Voltage drop, 3 conductors: 0.3 V/A.km
4C X 185 Sq.mm
Nexans ref. 24185SXZHSH30BS0
- Conductor shape: Sector-shaped
- Conductor cross-section: 185 mm²
- Approximate weight: 9367 kg/km
- Nominal outer diameter: 52.3 mm
- Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
- Permissible current rating in open air: 463 A
- Permissible current rating when buried: 324 A
- Voltage drop, 3 conductors: 0.26 V/A.km
4C X 240 Sq.mm
Nexans ref. 24240SXZHSH30BS0
- Conductor shape: Sector-shaped
- Conductor cross-section: 240 mm²
- Approximate weight: 11790 kg/km
- Nominal outer diameter: 58.2 mm
- Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
- Permissible current rating in open air: 546 A
- Permissible current rating when buried: 375 A
- Voltage drop, 3 conductors: 0.21 V/A.km
4C X 300 Sq.mm
Nexans ref. 24300SXZHSH30BS0
- Conductor shape: Sector-shaped
- Conductor cross-section: 300 mm²
- Approximate weight: 14380 kg/km
- Nominal outer diameter: 64.9 mm
- Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
- Permissible current rating in open air: 628 A
- Permissible current rating when buried: 419 A
- Voltage drop, 3 conductors: 0.18 V/A.km
4C X 400 Sq.mm
Nexans ref. 24400SXZHSH30BS0
- Conductor shape: Sector-shaped
- Conductor cross-section: 400 mm²
- Approximate weight: 18833 kg/km
- Nominal outer diameter: 72.9 mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 731 A
- Permissible current rating when buried: 439 A
- Voltage drop, 3 conductors: 0.17 V/A.km
Description
Description
Standards
-
InternationalIEC 60332-3-24 Cat.C
-
NationalBS 6724
Scope
This specification covers four core, XLPE insulated cables for use in Qatar Power Systems ,Street lightning and Small wiring systems. These cables are complying with BS 6724 and QCS 2014 Standards .
Design
1. Conductor
Plain annealed high-conductivity Stranded Copper Class 2 conforming to BS EN 60228
2. Insulation
XLPE insulation Type GP8 conforming to BS 7655-1
3. Filling or Bedding
Extruded HFFR
4. Armour
Single layer of Galvanised Steel Wires (GSWA)
5. Outer Sheath
Halogen Free Flame Retardant (HFFR)
- Flame retardant : IEC60332-3-24 CAT C
- Colour : Black
Marking
NO.OF CORES X Sq.mm CU/XLPE/SWA/HFFR 600/1000 V BS 6724 MADE IN QATAR QICC-NEXANS Years Meters
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania