Description
Description
Application
For use in household appliances such as washing machines, spin dryers and refrigerators. Generally unsuitable for outdoor use or industrial applications.
- Conductor
Stranded bare copper class 5 to BS EN 60228.
- Insulation
Polyvinyl chloride "PVC"
- Outer sheath
Polyvinyl chloride "PVC"
Installation
In conduit, insulated support, ducts... in coverd and dry place.
Packing
The packing will be in coils with 100 m.
Marking
no of cores x conductor size mm2 Cu / PVC / PVC H05VV-F 300/500 V BS 6500 MADE IN QATAR QICC-Nexans Year Meters
Permissible current and voltage drop are given
For conductor laid alone in insulating tube on a wall Temperature = 30°C.
Permanent operation If conditions are different, apply correction factors from IEC 60364-5-52 standard or other equivalent national standard Voltage drop Calculated with cosj = 0,8
Characteristics
Construction characteristics | |
---|---|
Conductor material | Bare copper |
Insulation | PVC |
Outer sheath | PVC-compound TM3 |
Conductor flexibility | Stranded class 5 |
Electrical characteristics | |
Rated Voltage Uo/U (Um) | 300 / 500 V |
Mechanical characteristics | |
Mechanical resistance to impacts | Low |
Usage characteristics | |
Max. conductor temperature in service | 70°C |
Short-circuit max. conductor temperature | 160°C |
Operating temperature, range | -5 .. 60°C |
Weather resistance | Good |
Bending factor when installed | 8(xD) |
Bending factor when laying | 4(xD) |